Monday, October 12, 2020

Installation Guidelines of Metal Face Seal

 

Mechanical Face seals are fitted in a Groove of retaining housing, to form the sealing at the adjoining faces. Metal faces are precision Lapped. The ramp angle of Seal and Housings are slightly different and form a wedge for the rubber ring to slide into and form a compressed profile giving load on the seals and making it intact. The installation guidelines are aimed to protect the precision lapped and Functional metal sealing faces. The more precautions taken, the more Likely the seals will last in the field.



Steps by Step Seal Installation Guidelines

1. Arrange Right Duo cone Seal, Installation Tool, Seal-O-Fix Spray, Mallet, Lint

Free Cloth, etc. as shown below before starting actual seal installation in the

housing cavity.

2. Check you are using appropriate tool part number, and design provided by SAP Parts™ for the Metal Face Seals. Note: – Each seal has a different Tool. Check  Seal face, O-Ring & housings are clean and free from any mechanical damage, dent, etc.

3. Apply Seal-O-Fix on Seal face and clean the Seal using Lint-Free Wipe. Ensure the seal face be thoroughly cleaned and no fine particles of dust should  remain on it...Do never use Ethanol, Oil or Grease for lubricating the O-Ring.

4. Put the O-Ring on the Seal Ramp and check it is properly placed on the metal ring ramp. Check there is no skewing or twisting of O-Ring, and Hold the O-Ring on the Seal Ramp and engage the Lip of the tool

between the gap of O-Ring and seal face inside the circular guideway groove of the Tool.