Mechanical Face seals are fitted in a Groove of retaining housing, to form the sealing at the adjoining faces. Metal faces are precision Lapped. The ramp angle of Seal and Housings are slightly different and form a wedge for the rubber ring to slide into and form a compressed profile giving load on the seals and making it intact. The installation guidelines are aimed to protect the precision lapped and Functional metal sealing faces. The more precautions taken, the more Likely the seals will last in the field.
Steps by Step Seal Installation Guidelines
1. Arrange Right Duo cone Seal, Installation Tool,
Seal-O-Fix Spray, Mallet, Lint
Free Cloth, etc. as shown below before starting actual seal
installation in the
housing cavity.
2. Check you are using appropriate tool part number, and
design provided by SAP Parts™ for the Metal Face Seals.
Note: – Each seal has a different Tool. Check
Seal face, O-Ring & housings are clean and free from any mechanical damage,
dent, etc.
3. Apply Seal-O-Fix on Seal face and clean the Seal using
Lint-Free Wipe. Ensure the seal face be thoroughly cleaned and no fine
particles of dust should remain on
it...Do never use Ethanol, Oil or Grease for lubricating the O-Ring.
4. Put the O-Ring on the Seal Ramp and check it is properly
placed on the metal ring ramp. Check there is no skewing or twisting of O-Ring,
and Hold the O-Ring on the Seal Ramp and engage the Lip of the tool
between the gap of O-Ring and seal face inside the circular
guideway groove of the Tool.
5. Bring the edges of the tool bracket close to each other
and hold the seal firmly in the clamp formed. This makes the Seal Guided in the
Install Tool.